Cooling Principle
The basic idea behind this Munters PreCooler technology is the increase of the combustion air density by reduction of the combustion air temperature - through adiabatic cooling. The PreCooler Systems are equipped with high efficiency cooling media available in either CELdek® or the non-flammable GLASdek®.

Design features
Self-supporting or non-self-supporting stainless steel frames for the pads and the mist eliminators
Pads made of paper fibres (CELdek®) or glassfibre material (GLASdek® - not flammable)
Water circulating system including stainless steel piping, valves and water tank
Sensors: Thermometer probe in front of/behind the cooler, conductivity measurement and, if necessary, pH adjustment of the circulating water
Biocide treatment
Blow down unit
Automatic operation and remote start-up and shutdown
Antifreeze
Benefits
-
Increased Power Output
The water is evaporated to pure cold vapour by the Munters PreCooler. This produces a cooling effect which provides an intake air at higher density. This allows the gas turbine to achieve increased power output (at least 5-6%, and up to 60% percent in very hot or dry climates) and operating efficiency.
-
Low Investment and Operational Costs
By using natural principles, the Munters PreCooler has a low investment and operational cost, which allows for very short pay-back periods of 12-24 months. The utility costs of the system are water consumption of normally 0.6-1.3m³ per additional MWH produced and power consumed by the feed pumps which is less than 0.5% of the additional power produced. For new installations Munters is able to offer the additional advantage of integration of the intake air filtration into the PreCooler. This substantially reduces the investment cost of both air filters and coolers by supplying one combined housing.
-
Simple Installation
Suited for new plants as well as retrofits!
-
Filtration Ability
An additional benefit of the Munters PreCooler is the air filtration ability. If installed prior to the first filter stage, it will remove approximately 90% of the particles normally removed by the first air filter stage. This significantly increases service life and therefore reduces the maintenance costs. This benefit is also extended to the fine filters, where the dust load is reduced by about 30%.
-
Noise Control
Due to the PerCooler's positioning on the intake air system, noise reductions of between 2-10 dB are possible depending on the frequency band.
-
Low Pressure Drop
Standard pressure drop of a Munters PreCooler is only 50-100 Pa, which is negligible when compared with the pressure drop of 250-1200 Pa by standard air filters. The PreCooler provides aerosol-free cooled air at a constant pressure drop throughout the year.
-
Long lasting media
Typically Munters media is replaced in gas turbines after 6-8 years or even thereafter.